ROZ1MZ1-K(AS+)

ROZ1MZ1-K(AS+)

The ROZ1MZ1-K (AS+) cables are those indicated for the connection of measuring, control and signalling instruments. They have a collective screen to avoid interference and reinforcement of galvanized steel wires that confers high mechanical performance. They are used where it is required to guarantee the supply of halogen-free, non-propagating and fire-resistant cables, the supply to emergency equipment such as signalling, smoke extractors, acoustic alarms, water pumps, etc.

  • Construction Standard: UNE-EN 50525-3-31.
  • Low Voltage Directive (LVD) compliant: 2014/35/UE
  • Construction Products Regulation (CPR) – (EU) Nº 305/2011: Reaction to fire Cca-s1b, d1, a1
  • DoP Number: C007-ENG- ROZ1MZ1K(AS+)
  • RoHS compliant.
  • Suitable for Industrial use / Potentially explosion hazard locations (ATEX area).

Conductor: Electrolytic copper, class 5 (flexible), according EN 60228 and IEC 60228.
Insulation: Mica tape + Cross-linked polyethylene (XLPE).
Screen: Aluminum/Mylar
Internal Outer sheath: Halogen free compound.
Armour: Galvanized Steel wire.
Outer sheath: Halogen free compound.
Nominal Voltage: 300/500 V
Nominal test : 1.500 V.ac
Maximum conductor temperatures: Normal operation 90°C Short circuit. Short circuit (5sec) 250°C

  • Non-flame propagation according to UNE-EN 60332-1-2, EN 60332-1-2 e IEC 60332-1-2.
  • Non-fire propagation according to UNE-EN 60332-3, EN 60332-3 e IEC 60332-3.
  • Low halogen content according to UNE-EN 60754, EN 50267 e IEC 60754.
  • Low corrosive gas emission according to UNE-EN 60754-2 e IEC 60754-2.
  • Low smoke emission according to UNE-EN 61034-2 e IEC 61034-2.
  • Fire reaction (CPR) Cca-s1b, d1, a1.
  • UV resistance (1 cycle) according to UNE 211605.
  • Water absorption resistance.
  • High cold resistance.
  • Impact and rodent resistance.
  • Fire resistance.
  • Electromagnetic protection.

Available on request

  • Hydrocarbons and oil resistance according to UIC-895 OR.
  • UV resistance (> 10 cycles) according to UNE 211605.
  • Rated voltage 450/750V.

ROZ1MZ1-K(AS+) 300/500V

Section Resistance at 20 °C

(Ohm/km)

Conductor Class External diameter (mm) Weight (kg/m) CPR
2X1,5 13,3 5 13,2 0,34 Cca-s1b-d1-a1
3X1,5 13,3 5 13,7 0,37 Cca-s1b-d1-a1

ROZ1MZ1-K(AS+) 450/750V

Section Resistance at 20 °C

(Ohm/km)

Conductor Class External diameter (mm) Weight (kg/m) CPR
2X1,5 13,3 5 13,2 0,34 Cca-s1b-d1-a1
3X1,5 13,3 5 13,7 0,37 Cca-s1b-d1-a1

 

*The values of the outer diameters are approximate, always within production tolerance. For more information, please contact us.