HFFR, screened and armoured cables RZ1KZ1MZ1-K(AS), are highly recommended for interconnection between frequency inverters and motors. Can be installed in hazardous areas with explosive gas atmospheres (ATEX) or with risk of fire and in general, where the cable is subject to risk of mechanical aggression.

  • Construction Standard: IEC 60502-1, UNE 21123-4
  • Low Voltage Directive (LVD) compliant: 2014/35/UE
  • Construction Products Regulation (CPR) – (EU) Nº 305/2011: Reaction to fire Cca-s1b, d1, a1.
  • DoP Number: C011-ENG-RZ1KZ1MZ1K
  • RoHS compliant.
  • Suitable for Industrial use / Potentially explosion hazard locations (ATEX area).

Conductor: Flexible electrolytic copper conductor (Class V) according to UNE-EN 60288 and IEC 60228
Insulation: Cross-linked Polyethylene (XLPE), type DIX 3 according UNE 21123, UNE HD 603 and XLPE according IEC 60502.
1º Inner sheath: Thermoplastic polyolefin sheath DMZ-E type according to UNE 21123 and ST8 according to IEC 60502-1
Screen: Outer conductor of copper wires and contrahelical copper wires.
2º Inner sheath: Thermoplastic polyolefin sheath DMZ-E type according to UNE 21123 and ST8 according to IEC 60502-1
Armour: Crown galvanized steel wire according to IEC 60502-1 and UNE 21123-4
Outer sheath: Thermoplastic polyolefin sheath DMZ-E type according to UNE 21123 and ST8 according to IEC 60502-1
Nominal Voltage: 0,6/1 kV C.A
Voltage Test: 3.500 V C.A.
Maximum conductor temperatures: Normal operation 90°C. Short circuit (5sec) 250°C

  • Non-flame propagation according to EN 60332-1-2, IEC 60332-1-2.
  • Non-fire propagation according to EN 60332-3-24, IEC 60332-3-24.
  • Low halogen content according to EN 60754-2, EN 60754-1, IEC 60754-2, IEC 60754-1.
  • Low corrosive gas emission according to EN 60754-2, IEC 60754-2.
  • Low smoke emission according to EN 61034-2, IEC 61034-2.
  • Fire reaction (CPR) Cca-s1b, d1, a1.
  • UV resistance (1 cycle) according to UNE 211605.
  • Water absorption resistance.
  • High cold resistance.
  • Impact and rodent resistance.
  • Copper concentric conductor that makes the protection function as well reduces the electromagnetic emission and helps the return of high frequency currents.

Available on request

  • Hydrocarbons and oil resistance according to UIC-895 OR.
Section (mm2) Resistance at 20 °C

(Ohm/km)

Nominal outer diameter (mm) Weight (kg/m) CPR
2X2,5/2,5 7,98 18,9 0,72 Cca-s1b-d1-a1
2X35/16 0,554 32,6 2,34 Cca-s1b-d1-a1
3×2,5/2,5 7,98 19,4 0,76 Cca-s1b-d1-a1
3×4/4 4,95 20,8 0,88 Cca-s1b-d1-a1
3×6/6 3,3 22,1 1,02 Cca-s1b-d1-a1
3×10/10 1,91 25,4 1,43 Cca-s1b-d1-a1
3×16/16 1,21 27,8 1,78 Cca-s1b-d1-a1
3×25/16 0,78 32,1 2,31 Cca-s1b-d1-a1
3×35/16 0,554 35,4 2,98 Cca-s1b-d1-a1
3×50/25 0,386 39,2 3,75 Cca-s1b-d1-a1
3×70/35 0,272 43,9 4,84 Cca-s1b-d1-a1
3×95/50 0,206 49,3 6,35 Cca-s1b-d1-a1
3×120/70 0,161 56,1 7,88 Cca-s1b-d1-a1
3X150/70 0,129 62,4 9,47 Cca-s1b-d1-a1
3X185/95 0,106 68,2 11,28 Cca-s1b-d1-a1
3X240/120 0,0801 73,5 13,66 Cca-s1b-d1-a1
12X2,5/4 7,98 27,3 1,48 Cca-s1b-d1-a1

 

*The values of the outer diameters are approximate, always within production tolerance. For more information, please contact us.