RHOVMV

The installation of those cables is highly recommended in-service stations (gas stations), petrochemical plants, flammable products warehouses, etc. Likewise, it can be used in installations as production plants and in general. The installation of those cables is highly recommended in-service stations (gas stations), petrochemical plants, flammable products warehouses, etc. Likewise, it can be used in installations as production plants and in general.

  • Technical designation RHOVMV rigid copper conductor class 2.
  • Technical designation RHOVMV-K Flexible copper conductor class 5.
  • Construction Standard: UNE -EN-50288-7, IEC-60288.
  • Low Voltage Directive (LVD) compliant: 2014/35/UE
  • Construction Products Regulation (CPR) – (EU) Nº 305/2011: Reaction to fire Eca.
  • RoHS compliant.
  • Suitable for Industrial use / Potentially explosion hazard locations (ATEX area).
Conductor Rigid electrolytic copper conductor (Class II) or flexible (class V) according to UNE-EN 60288
Insulation Cross-linked Polyethylene (XLPE), according UNE EN 50288-7
Screen (Individual / overall) Polyester tape + tinned copper drain wire + aluminum/mylar tape with 100% coverage
Inner sheath Thermoplastic polyolefin according EN 50288-7
Armour Crown galvanized steel wire
Sheath Thermoplastic polyolefin according EN 50288-7
Nominal voltage 300/500 V
Test voltage 2.000 V.ac
Maximum conductor temperatures Normal operation 90°C Short circuit
Short circuit (5sec) 250°C
  • Non-flame propagation according to EN 60332-1-2, IEC 60332-1-2.
  • Fire reaction (CPR) Eca.
  • UV resistance (1 cycle) according to UNE 211605 and EN 50289-4-17.
  • Suitable for all type of installations withstand damp conditions including immersion in water (AD7).
  • High cold resistance, cable designed to operate reliably at -40ºC in fixed installations and protected installations.
  • Impact resistance: AG4. High severity.
  • Rodent resistance.

AVAILABLE ON REQUEST

  • Hydrocarbons and oil resistance according to UIC-895 OR.
  • Flexible / rigid conductor according to UNE EN 60228.
  • Non-fire propagation according to EN 60332-3-24, IEC 60332-3-24.
  • Low halogen content (≤ 14%) according to EN 60754-2, EN 60754-1, IEC 60754-2, IEC 60754-1.
Section Resistance at 20 °C

(Ohm/km)

Conductor Class External diameter (mm) Weight (kg/m) CPR
2X2X1,5 13,3 5 16,2 0,485 Cca-s1b-d1-a1
3X2X1,5 13,3 5 16,9 0,52 Cca-s1b-d1-a1
4X2X1,5 13,3 5 18,1 0,62 Cca-s1b-d1-a1
5X2X1,5 13,3 5 19,4 0,75 Cca-s1b-d1-a1
6X2X1,5 13,3 5 22,2 0,97 Cca-s1b-d1-a1
10X2X1,5 13,3 5 26,3 1,31 Cca-s1b-d1-a1
12X2X1,5 13,3 5 29 1,53 Cca-s1b-d1-a1
20X2X1,5 13,3 5 36 2,89 Cca-s1b-d1-a1
24X2X1,5 13,3 5 38,5 3,62 Cca-s1b-d1-a1
2X3X1,5 13,3 5 17,2 0,55 Cca-s1b-d1-a1
6X3X1,5 13,3 5 25 1,21 Cca-s1b-d1-a1
10X3X1,5 13,3 5 29,5 1,63 Cca-s1b-d1-a1
12X3X1,5 13,3 5 32,7 2,06 Cca-s1b-d1-a1
20X3X1,5 13,3 5 39,9 2,93 Cca-s1b-d1-a1

 

*The values of the outer diameters are approximate, always within production tolerance. For more information, please contact us.